Home     ACDC-400 Digital AC/DC Clamp-on Multimeter
ACDC-400 Digital AC/DC Clamp-on Multimeter

ACDC-400 Digital AC/DC Clamp-on Multimeter


AC/DC : 400A; 600V,...

  • AC/DC Current up to 400A
  • AC/DC Voltage up to 600V


EUR 187.99
excl. VAT

Article code: 110-400

ACDC-400 Digital AC/DC Clamp-on Multimeter


  • Product info
  • Related products

The ACDC-400 clamp meter is full featured with wide measurement capabilities. It measures both AC and DC Current to 400 amps, AC and DC Voltage to 600V, plus Resistance and Continuity. The ACDC-400 also offers software features of Min/Max and Relative measurements with a large digital and analog combined display and backlight.

  • Display : 3-3/4 digits 4000 counts LCD display
  • Update Rate : 2 per second nominal
  • Polarity : Automatic
  • Power Supply : 2 standard 1,5V AAA battery
  • Battery Life : typical 25 hours
  • APO Timing : idle for 30 minutes
  • Low battery : indication on LCD; approx. 2,4V
  • Environment : indoor operation, below 2000 m
  • Temperature Operating : 5°C to 40°C (41°F to 104°F)
  • Humidity Operating : < 80% RH
  • Storage: -10°C to 60°C (14°F to 122°F), < 80% RH
  • Jaw opening : 27 mm max
  • Dimensions : 202 x 70 x 40 mm
  • Weight : 254 gm

Features
- AC/DC Current up to 400A
- AC/DC Voltage up to 600V
- Resistance measurement
- Continuity test
- Data Hold
- MAX/MIN recording
- Relative measurement
- Backlight
- Analog bargraph
- Auto or Manual range selection
- Max Conductor 29,97 mm (1.18”)
- Includes carrying case
- CAT III 600V

EMC
This apparatus was designed in accordance with EMC standards in force and its compatibility has been tested in accordance EN61326 (1997) + A1 (1998) + A2 (2001).

Safety :
Comply with : EN 61010
Insulation : Class 2, double reinforced insulation
Pollution : Level 2
For inside use, max height : 2000m
Over voltage : CAT III 600V (between ground & input terminal)

Certifications :
Safety LVD : Meets EN60101-1:2001; EN61010-2-032(2002), Category II- 600 Volts ac & dc; pollution degree : 2; class 2
CE EMC : EN61326-1:2006

Standard Accessories:
- Instrument
- Test leads (MTL-90B)
- Rubber test lead holster (MTL-CAP)
- User’s manual
- Carrying case (SV-U)
- Batteries


Electrical Specifications (23 °C ± 5 °C) < 75%RH

DC Voltage
Range
Accuracy


400.0 mV 4.000V, 40.00V, 400.0V
± (0.8% rdg + 2 dgts)


600V
± (1.0% rdg + 2 dgts)


Input impedance
10 MΩ 30pf nominal ( 100 MΩ for 400.0mV range)




Max input
600 VDC






AC Voltage (sinusoidal)
Range
Frequency
Accuracy

400.0mV
40Hz to 60Hz
± (1.0% rdg + 50 dgts)

4.000V, 40.00V, 400.0V
50Hz to 500Hz
± (1.0% rdg + 3 dgts)

600V
50Hz to 500Hz
± (1.2% rdg + 3 dgts)




Input impedance
10MΩ, 30pf nominal ( 100 MΩ for 400.0mV range)
Max input
600 VAC rms






DC Current (Clamp-On)
Range
Accuracy


0.00A to 40.00A
± (2.0% rdg + 10 dgts)


40.0A to 400.0A
± (2.0% rdg + 10 dgts)





Max current
400A rms continuous; 600 A rms ( 60 seconds)


AC Current (Clamp-On) (sinusoidal)
Range
Frequency
Accuracy

0.00A to 40.00A
50Hz to 60Hz
± (2.0% rdg + 10 dgts)

40.0A to 400.0A
50Hz to 60Hz
± (2.0% rdg + 10 dgts)
Max current
400A rms continuous; 600 A rms ( 60 seconds)




Resistance
Range
Accuracy


400.0 Ω
± (1.0% rdg + 5 dgts)


4.000kΩ, 40.00k Ω,
400.0k Ω, 4.000M Ω
± (1.0% rdg + 3 dgts)


40.00MΩ
± (3.0% rdg + 3 dgts)





Open Circuit Voltage
0.45 Vdc typical; 1.5 Vdc typical for 400.0 Ω
Continuity Tester
Open Circuit Voltage: 1.4Vdc typical
Audible threshold: < 40 Ω