Home     KANE 77 portable carbon monoxide monitor & CO alarm
KANE 77 portable carbon monoxide monitor & CO alarm

KANE 77 portable carbon monoxide monitor & CO alarm


0 ... 999 ppm CO

  • Range : 0-999 ppm
  • Accuracy : as per EN 50543 : 2011
  • Accuracy : ±3 ppm 0 to 100 ppm
  • Audible Alarm : Preset at 30 ppm


EUR 199.00
excl. VAT

Article code: 274-0077

KANE 77 portable carbon monoxide monitor & CO alarm


  • Product info

Measures from 0 to 999 ppm CO. Long life CO sensor with 5 year expected life. One button ON with Auto Zero. Captures maximum value.

The KANE77 is used to monitor carbon monoxide (CO) levels in commercial and residential living spaces, warehouse operations, combustion engine repair facilities, public facilities and any other indoor areas where people may work or live.

  • Range : 0-999 ppm (parts per million)
  • Resolution : 1 ppm
  • Accuracy : 3 ppm 0 to 100 ppm (EN 50543 : 2011)
  •                5% reading > 101 ppm
  • Audible alarm : preset at 30 ppm
  • Visual indication : LCD and LED
  • Battery : 9V alkaline
  • Battery life : up to 250 hours
  • Ambient temperature : 0-40°C
  • Dimensions : 110 x 66 x 38 mm excluding clip (45mm including clip)
  • Weight : 180 grams
  • Warranty : 1 year
Info
The full-featured, compact design of the KANE77 allows for easy use in almost any normal working environment. It is not designed for use in areas designated as “confined spaces” where other toxic gases may be present or in designated zoned areas where Intrinsic Safety products are mandatory.

- Preset Alarms
- Vibrating Alarm
- Visual three colour LED :
        OFF : 0-1 ppm
        GREEN : 2-9 ppm
        AMBER : 10-29 ppm
        RED : 30ppm or higher
- Audible tone : if readings 30 ppm or above
- Data Hold
- Back lit display
- Battery Indication
Supplied with :
- CO Monitor with rubber sleeve and battery (fitted)
- User instruction manual
- Full 12 month traceable calibration certificate





Concentration of CO in Air and Inhalation Times & Toxic Symptoms (The effects can vary depending on size, age, sex and health)

10 ppm
The maximum allowable concentration for an 8 hour period without any known health risks according to the Department of Health and BS7967
30 ppm
The maximum allowable concentration for competent persons to work in when investigating reports of fumes according to BS7967
200 ppm
Mild headache, fatigue, dizziness and nausea after 2 to 3 hours
400 ppm
Frontal headache and nausea within 1 to 2 hours. Life threatening after 3 hours
800 ppm
Severe headache, dizziness and convulsions within 45 minutes.
Unconsciousness within 2 hours. Death within 2 to 3 hours
1600 ppm
Headache, dizziness and nausea within 20 minutes. Death within 1 hour
3200 ppm
Headache, dizziness and nausea within 5 to 10 minutes. Death within 30 minutes
62000 ppm
Headache, dizziness and nausea within 1 to 3 minutes. Death within 10 to 15
minutes
12800 ppm
Death within 1 to 3 minutes